The short answer
A PoE budget is the total wattage a network switch can deliver to all of its Power over Ethernet ports at once. To size one for cameras, add up the worst-case power draw of every camera on that switch (with infrared, heaters and pan/tilt motors included), add headroom for growth, and make sure the switch's total PoE budget, not just its per-port rating, covers it. Running out of budget is one of the most common reasons cameras reboot at night or drop offline in cold weather.
Port rating vs. total budget
Switch spec sheets list two different numbers, and mixing them up causes most PoE problems:
- Per-port power is the most a single port can deliver, set by the PoE standard it supports.
- Total PoE budget is the most the whole switch can deliver across all ports at the same time. A 24-port PoE+ switch can often power a few ports at full PoE+ wattage, but not all 24 at once.
A switch that "supports PoE+ on every port" can still run out of power long before every port is in use. Always check the total budget in the data sheet.
The PoE standards in plain English
The IEEE standards define how much power the switch sends and how much is guaranteed to arrive at the device after losses in the cable:
- PoE (802.3af, Type 1): 15.4 W from the switch, 12.95 W at the device. Fine for many fixed indoor cameras.
- PoE+ (802.3at, Type 2): 30 W from the switch, 25.5 W at the device. Common for outdoor cameras with heaters or strong infrared, and for multi-sensor cameras.
- PoE++ (802.3bt, Type 3): 60 W from the switch, 51 W at the device. Used by many PTZ (pan-tilt-zoom) cameras.
- PoE++ (802.3bt, Type 4): 90 W from the switch, 71.3 W at the device. Used by larger PTZ units with heaters and long-range illuminators.
Budget against the switch-side number. That is what comes out of your switch's budget, whatever the camera actually receives.
Where to find each camera's real draw
Every camera data sheet lists power consumption, usually as a PoE class plus a maximum wattage. A few things to watch for:
- Use the maximum, not the typical. A camera may draw much less during the day and much more at night when the infrared turns on.
- Heaters and blowers. Outdoor cameras with built-in heaters can draw far more on a cold January night than they did when they were installed in summer. This is the classic "cameras go down when it gets cold" problem.
- PTZ motors. Pan-tilt-zoom cameras spike when they move, and many need a PoE++ port or a dedicated injector.
- Accessories. Built-in speakers, audio, or wipers add to the total.
- PoE class. Some switches reserve power by the camera's declared class instead of what it actually draws. In that case, a Class 4 camera reserves a full PoE+ allotment even if it rarely uses it, so plan by class.
A simple way to do the math
- List every camera planned for the switch, with its maximum wattage (or class allotment, if your switch allocates by class).
- Add any other PoE devices on the same switch: Wi-Fi access points, door controllers and readers for access control, VoIP phones, intercoms.
- Add the total and compare it to the switch's PoE budget.
- Leave headroom. Many integrators aim to keep the planned load well under the maximum, roughly 20 to 30 percent below, so there is room for added cameras and cold-weather peaks.
Example, using made-up round numbers for illustration: 12 indoor cameras at 7 W each, 6 outdoor cameras with heaters at 25 W each, and 2 PTZ cameras at 50 W each. That is 84 + 150 + 100 = 334 W before headroom. A switch with a 370 W budget would technically fit, but with almost no margin. A larger budget, or splitting cameras across two switches, is the safer plan.
Cable matters too
PoE runs over the same structured cabling as your data, so the cabling has to be done right:
- 100 meters (328 feet) is the limit for a standard Ethernet channel, including patch cords. Long outdoor runs to parking lots or fence lines often need an intermediate switch, a PoE extender or fiber to a remote enclosure.
- Use solid copper cable. Copper-clad aluminum (CCA) cable heats up and drops voltage under PoE load and is not compliant with the cabling standards.
- Higher power means more heat in bundles. For PoE++ cameras, larger cable bundles and hot ceiling spaces matter. Cat6 or Cat6A with good bundle management handles this better than tightly packed bundles.
- Certify the runs. A run that passes a basic link test but has a bad termination can work for data and still fail under PoE load.
Signs your PoE budget is too small
- Cameras that reboot or go dark at dusk, when infrared turns on.
- Outdoor cameras that drop offline in cold weather.
- New cameras that will not power up even though open ports are available.
- Switch logs showing ports denied power or "power budget exceeded."
- PTZ cameras that work until they move, then drop.
If you see these, check the switch's PoE status page first. Most managed switches show how many watts are allocated and how many remain.
Planning tips for new camera projects
- Plan the camera layout and the switch together, not one after the other.
- Put cameras on their own switch or VLAN where practical, so a busy office network and the camera system do not compete for power or bandwidth.
- Write down each camera's port, wattage and location. It makes troubleshooting and future additions much faster.
- Think about the next phase. If you expect to add cameras or access control doors next year, buy the budget for it now.
Strategix installs cameras from any manufacturer, plus access control and the structured cabling behind them, for businesses, VARs and MSPs across Kentucky, Southern Indiana, Indianapolis and Cincinnati. Learn more about our camera and access control installation and low voltage cabling, or request a quote and we will help you plan the cabling and PoE for your next camera project.